Outdoor microwave passive infrared composite intruder detector specification

Capture performance and avoid false alarms

The outdoor microwave passive infrared composite intruder includes both PIR and microwave technologies. The detection range is 15m90°. A telephoto lens is provided in the product for 23m5° and a barrier of 155°.

Outdoor microwave passive infrared composite intruder detectors should use 2 PIR channels with digital correlation technology and 2 microwave channels with shaking recognition technology to achieve reliable capture performance and avoid false alarms due to all of the following reasons:

Because the strong wind or clouds/solar conditions change, combining different temperatures of heating and cooling with different materials causes the background temperature to change rapidly.

Rain, hail and snow <br> <br> reflection

Move and shake objects such as bushes, leaves, and moving objects.

Scraped scrap pet and animal head up to 70cm

standard

The outdoor microwave passive infrared composite intruder meets EN-50131 safety level 3 and environmental level III. The product satisfies all requirements of the R&TTE Directive for its type. The detector should have a CE mark.

Installation flexibility

The detector installation height is between 1 and 2.7m.

The detector provides a dedicated professional rotating bracket with a vandal-proof concealed wiring and wall tamper, as follows:

Standard swivel bracket - supplied as standard with the detector.

Microwave Anti-collision Function The outdoor microwave passive infrared composite intruder has microwave anti-collision function and can install the DT detector in the vicinity or even face to face.

Anti-mask

The detector uses 4 active IR channels to continuously monitor the masking intention of the camera. The AM signal is provided via a separate relay output (also showing any fault in the detector) or via a 4-wire bus mounted on the ProSYS bus.

Dirty lens reminder
The detector has a "dirty lens" reminder function that can be alerted through a separate output port when the lens of the detector needs cleaning. Active IR channels used for anti-masking will also constantly check the transparency of the lens, but use different methods of determination. The "dirty lens" alert will be provided via a separate 70mA open collector output port on the terminal module or via the ProSYS bus.

Environmental rating

The environmental rating of the detector is IP65. Used to protect the detector from horizontal spray.

Protective cover

The detector has an integrated protective cover to protect against sunlight, rain, hail, snow, dust and bird droppings.

Walk test LED

The detector has 3 high-visibility LEDs that support the detector walk test in outdoor light conditions.

Remote control and diagnostics (when installed on ProSYS bus) When installed on a 4-wire ProSYS bus, the detector should have remote control diagnostics. This will provide:

Faster, more cost-effective installation: Wiring requirements in relay mode Each detector's wiring is directly connected to the panel (star configuration only). Through the bus wiring, the detectors can be linked between them, saving a lot of wiring time and shortening the installation time.

Fewer wires and easier installation: In bus mode, only 4 wires are required for all installations. In repeater mode, up to 10 wires may be required to implement the full functionality of the detector: Basic installation of alarms and tamper devices requires 4 wires, and AM output ports require an additional 2 wires. The use of support LEDs, setup/unset controls, remote test controls, and functions for "dirty lens" reminders require additional cabling connections.

Remote diagnosis: The remote diagnosis function saves on-site visits according to the requirements of the contractor. If on-site maintenance is required, the contractor can know the exact nature of the problem in advance, thereby saving time and effort on site. The remote diagnostics function is:

The voltage input to the detector is measured.

<br> <br> measuring software version and the signal from the noise level detector 4 channels

Remote Control: All settings of the detector should be adjusted from the ProSYS keyboard or via upload/download software, saving installation and adjustment time. In addition, the detection sensitivity setting can be changed to avoid false alarm issues until the contractor can access the site. Remote control settings should include:

LED control: 3LED/1LED/off detection sensitivity: (low, medium, normal, high). High detection sensitivity will disable the shake recognition MW range: minimum, 20%, 40%, 60%, 80%, maximum (maximum 23m), trimmer (MW range is defined by the trimmer on the PCB)

Alarm logic: and/or (for OR logic, probes in MW or PIR channels will trigger an alarm)

Lens type: wide/telephoto (used to synchronize the detector's processor settings with the mounted lens)

Anti-mask: On/Off Follow Arming: On/Off