Gear pump common failure and troubleshooting

Fault phenomenon: the pump can not discharge 1, the cause of the malfunction: a, the opposite direction of rotation; b, suction or discharge valve is closed; c, the inlet without material or pressure is too low; d, viscosity is too high, Troubleshooting: a, confirm the direction of rotation; b, confirm whether the valve is closed; c, check the valve and pressure gauge; d, check the liquid viscosity, low speed operation by the speed ratio of the flow rate is there, if the flow, the inflow is insufficient. Symptom two: the pump flow less than 1, the cause of the malfunction: a, suction or discharge valve is closed; b, the inlet pressure is low; c, the outlet pipe plugging; d, packing box leakage; e, low speed. 2, troubleshooting: a, to confirm the valve is closed; b, check the valve is open; c, to confirm the discharge is normal; d, tighten; a large number of leaks affect production, should stop running, disassembly inspection; Axis actual speed; Symptom 3: Abnormal sound 1, Malfunction reasons: a, the coupling eccentric or poor lubrication b, motor failure; c, reducer abnormalities; d, shaft seal installed poor; e, shaft deformation or wear . 2, troubleshooting: a or find filling grease; b, check the motor; c, check the bearings and gears; d, check the shaft seal; e, parking disintegration inspection. Symptom 4: the current is too large 1, the cause of the malfunction: a, the outlet pressure is too high; b, the melt viscosity is too large; c, shaft seal assembly bad; d, shaft or bearing wear; e, motor failure. The valve inlet pump industrial washing machine 2, troubleshooting: a, check the downstream equipment and pipelines; b, test the viscosity; c, check the shaft seal, appropriate adjustments; d, after parking check, hand crank car is overweight; . Fault phenomenon five: the pump suddenly stopped 1, the cause of the malfunction: a, power failure; b, motor overload protection; c, coupling damage; d, the outlet pressure is too high, interlocking reaction; e, Shaft and bearing stuck stuck. 2, troubleshooting: a, check the power; b, check the motor; c, open the safety cover, disk car inspection; d, check the instrument interlock system; e, after parking, reversing confirmation; More gear pump knowledge, please see: Fluid Encyclopedia?

ABS Blade Ceiling Fan Without Light

Small Ceiling Fans Without Lights,Low Profile Ceiling Fan Without Light,Contemporary Ceiling Fans Without Lights,Flush Mount Ceiling Fan No Light

JIANGMEN ESCLIGHTING TECHNOLOGY LIMITED , https://www.windfansummer.com

This entry was posted in on